SDD DINsafe Surge Diverter - SDD1-50-275

SDD DINsafe Surge Diverter - SDD1-50-275

Distribution Board Surge Protection
Use DIN compliant SDD Surge Diverters for distribution boards or for point of entry protection in small industrial and domestic applications. Two layers of surge protection devices greatly improve the performance and reliability of the surge protection system.

All Mode Protection
Protection is provided for all combinations of lines ensuring the maximum level of protection is achieved at all times.

Thermal Sensing
Sustained overvoltages can cause components to overheat and degrade. Thermal sensing warns of this condition without disconnecting the protection.

LED Status Active Display
The LED display indicates phase status and normal operation when all LEDs are lit. An extinguished LED indicates a component failure or thermal overload, also initiating the optional external alarm.

Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.

Electrical Specifications
Connection type: Shunt
Modes of protection: L-N, L-PE, N-PE 
Phases: 1  
Nominal voltage Uo: 230 VAC 
Short circuit withstand level I SCCR: 25 kA 
Maximum backup fuse (gL/gG): 32 A 
L-N
Maximum continuous voltage Uc: 275 VAC 
Maximum load current I L: – 
Maximum discharge current (8/20 µs) I max: 50 kA
Lightning impulse current (10/350 µs) I imp: 3.25 kA 
Nominal discharge current (8/20 µs) I n: 20 kA
Voltage protection level @ 3 kA 8/20 µs Up: < 800 V 
Voltage protection level @ In Up: < 1400 V
Response time t A: < 5 ns 
Temporary overvoltage (TOV) UT: 337 V / 5 s (Withstand) & 442 V / 120 min (Safe Failure)
N-PE
Maximum continuous voltage UC: 255 VAC
Maximum discharge current (8/20 µs) I max: 25 kA
Lightning impulse current (10/350 µs) I imp: –
Nominal discharge current (8/20 µs) I n: 10 kA
Voltage protection level @ 1 kV/ µs Up: < 1200 V
Voltage protection level @ In Up: < 1500 V
Response time t A: < 100 ns < 100 ns
Temporary overvoltage (TOV) UT: 1200 V / 0.2 s
Follow current interrupt rating I fi: 100 A
Earth leakage current I PE: < 10 µA 
Indication
Display: LED status per phase
External alarm: Active alarm optional
Display / Alarm function: Power fail safe, thermal overload, SPDT voltage free contact
Alarm isolation: 4 kV
Mechanical Specifications
Operating temperature: -40 to +70 ºC
Humidity Range: 5 to 95% non–condensing
Terminal capacity – power: 2.5 – 16 mm2
Terminal capacity – alarms: 0.5 – 2.5 mm2 
Terminal screw torque – power: 2.0 Nm 
Terminal screw torque – alarm: 0.5 Nm
Environmental / Location: IP 20 / Indoor
Dimensional Drawing: A (B with alarm)
Device width: 18 mm (36 mm/alarm)
Mounting: TS35 DIN rail
Enclosure / Colour: Metal / Black 

Standards
IEC 61643-11:2011 SPD connected to low-voltage power systems - Type 2
AS/NZS 1768:2007 A.C. power system SPD - Cat C, B
UL 1449 3rd edition Low voltage SPD - Type 2
IEEE 62.41.2:2002 Low voltage SPD - Cat B 

Weight: 150 g
Customs Tariff 85354010